제품특성
CGN99 H/S (H/L)는 hypercardioid 극지방의 패턴이며 사람들이 더 큰 거리에서 마이크로폰으로 말하는 모든 쪽(특히 예배 센터의)에서 소음이 전형적으로 발생하는, 또는 몇 명의 말하는 사람이 나란히 서서 모으게 되는 상황에 픽업이 가장 알맞다. 다른 길이는 이용할 수 있다..exible 접합 부분은 어떤 말하는 사람 위치라도 거위 목 모양의 연장 또는 관의 최적 조건 정렬을 확실하게 한다.
GENERAL
Audio Frequency bandwidth 50 to 19000 Hz
Sensitivity 12 mV/Pa
Equivalent Noise Level 21 dB-A
Signal to Noise 73 dB-A
Electrical Impedance 600 Ohms
Recommended Load Impedance 2000 Ohms
Audio Frequency bandwidth 50 to 19000 Hz
Sensitivity 12 mV/Pa
Equivalent Noise Level 21 dB-A
Signal to Noise 73 dB-A
Electrical Impedance 600 Ohms
Recommended Load Impedance 2000 Ohms
POLAR PATTERNS
Polar Pattern hypercardioid
Polar Pattern hypercardioid
POWERING INTERFACE
Voltage 9 to 52 V
Current 3 mA
Voltage 9 to 52 V
Current 3 mA
AUDIO OUTPUT
Type Balanced XLR
Gender Male
Contacts 3-pin
Type Balanced XLR
Gender Male
Contacts 3-pin
DESIGN
Finish black
 
 
 
Lectern
Houses of worship
Conferencing

CGN 99 H/S (H/L)

  • Hypercardioid polar pattern
  • 30 or 50 cm (12 or 20 in.) long
  • 95° pickup angle
  • For acoustically difficult environments
  • Connects easily via XLR connector
The hypercardioid polar pattern with its narrow 95° pickup angle is suited best for situations where noise typically occurs from all sides (particularly in worship centers), where people talk into the microphone from a greater distance, or where several talkers are grouped side by side. Two different lengths are available. The .exible joint ensures optimum alignment of the gooseneck to any talker position. Several options are available for installation, i.e., stand, tabletop installation, and lockable.
Choosing polar patterns
Selecting the correct polar pattern for installed sound is difficult since it depends on a variety of factors. Of course the acoustics of the room play a key role. For highly reverberant rooms such as worship centers, a hypercardioid polar pattern will be the best choice to avoid high levels of unwanted noise. Correct placement of the loudspeakers is also essential. If the speakers project right at the capsule, a hypercardioid will be your best bet. The most difficult task, however, is trying to judge how the talkers will behave. For talkers who are inexperienced or move around a lot, be sure to choose a cardioid polar pattern for reliable pickup; talkers at a greater distance from the mic will be served best by a hypercardioid.

카테고리: , Brand: ,

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “CGN99H/L”

There are no reviews yet.

SHOPPING CART